A1:
- Disconnect
all Accessories from Gate, then try the Transmitter
to open/close.
- Dead
Battery, terminals disconnected or corroded.
- Interlock
Mechanism binding.
- Interlock
Solenoid not operating.
- Loose
or broken V-Belt.
- Control
Board damaged or plugs and terminals loose.
|
| |
A2:
- Disconnect
all Accessories from Gate, then try the Transmitter
to open/close.
- Current
Sensitivity not adjusted correctly (Gently turn full clockwise).
- Run
Timer set too low (Reference Gate Board Instructions).
- Low
Battery - Recharge.
- Tension
on V-Belt not adequate.
- Proximity
Switch engaging too soon.
- Gate
out of Balance - Adjust Spring Tension on Operator Arm (Remove
top side panel).
|
| |
A3:
- Disconnect
all Accessories from Gate, then try the Transmitter
to open/close.
- Short
circuit in electrical system.
-
Moisture in Push Button.
-
Moisture in Control Board Rcvr. - Dry out box and remove/replace
Control Board.
-
Transmitter button stuck.
-
Outside Radio interference - Change
-
Down Proximity Magnet not aligned properly.
- Low
Battery - Recharge.
|
| |
A4:
- Disconnect
all Accessories from Gate, then try the Transmitter
to open/close.
- Check
Interlock Mechanism on inside of the Operator. If it is not
moving freely by hand or with the override lever, try the following:
-
Remove the outside top skin adjacent to door and Oil the
Pivot Bolt.
-
Check Solenoid operation.
- Check
for broken Springs.
- Check
V-Belt tension.
|
| |
A5:
- Disconnect
all Accessories from Gate, then try the Transmitter
to open/close.
- Does
gate run only in open direction even if stopped mid-cycle?
If yes, then Proximity Switch "B" is stuck closed
and must be replaced.
Remove panel adjacent to door and Solder all wire splices.
|
| |
A6:
- Disconnect
all Accessories from Gate, then try the Transmitter
to open/close.
- Does
gate run only in closed direction even if stopped mid-cycle?
If yes, then Proximity Switch "A" is stuck closed
and must be replaced.
Remove panel adjacent to door and Solder all wire splices.
|
| |
|